This reference covers stock BMS settings for the ONYX 41Ah 72V battery. Identify the BMS variant before comparing or restoring values. These are recorded settings, not the temporary imbalance-recovery configuration.

ONYX 41Ah 72V BMS Variants

  • 80A BMS

    • charge overcurrent: 90000
    • discharge overcurrent: 90000
  • 100A BMS

    • charge overcurrent: 110000
    • discharge overcurrent: 110000

Higher current BMS units provide increased output but increase stress on aging cells.

Connector Limitation Note

  • SB50 connectors limit maximum output
  • upgraded connectors (e.g., OSE) reduce restriction

ONYX 41Ah 72V BMS Stock Configuration

  • Total Battery Capacity: 41000
  • Total Cycle Capacity: 32800

Capacity Configuration

FieldValue
Number of Cell20
Total Battery Capacity41000
Total Cycle Capacity32800
Cell Full Voltage4150
Cell Minimum Voltage3000
Cell Self Discharge0.2
Cell 100% Cap. Voltage4150
Cell 90% Cap. Voltage4075
Cell 80% Cap. Voltage4000
Cell 70% Cap. Voltage3900
Cell 60% Cap. Voltage3800
Cell 50% Cap. Voltage3700
Cell 40% Cap. Voltage3600
Cell 30% Cap. Voltage3450
Cell 20% Cap. Voltage3300
Cell 10% Cap. Voltage3150

Balancer Configuration

FieldValue
Start Voltage3900
Delta to Balance15
Balancer Enabled (On)Green
Bal. Only When Charging (On)Green

Function Configuration

FieldValue
SW Switch Circuit Enabled (Off)Gray
Display Celsius (Off)Gray

Protections

FieldTriggerReleaseDelay
Cell Over Voltage42504150
Cell Under Voltage27003000
Batt Over Volt.8500083000
Batt Under Volt.5400060000
Charge Over Curr.7000032
Discharge Over Curr. (80 Amp BMS)9000032
Discharge Over Curr. (100 Amp BMS)11000032
Charge Over Temp65552
Charge Under Temp-502
Discharge Over Temp6057.22
Discharge Under Temp-1002

NTC Enable

FieldBox
NTC1Checked
NTC2Checked
NTC3Checked
NTC4Checked
NTC5Not Checked
NTC6Not Checked
NTC7Not Checked
NTC8Not Checked

Level 2 Protections

FieldTriggerDelay
Level 2 Overcurrent720320
Level 2 Overvoltage44008
Level 2 Undervoltage25008

Level 3 Protections

FieldTriggerDelayReset
Level 3 Overcurrent (Short Circuit)20004005

Stock vs Temporary Recovery

Temporary recovery and balance optimization remain in the 41Ah battery reference. Restore the applicable stock settings after the documented recovery procedure. Do not combine values from different BMS variants.