A 72V ONYX uses a different voltage reference from its nominal label. Check the battery model and whether the reading is at rest or under load. Use the pack and cell references below alongside the battery’s actual behavior.

Cell Identification in Older References

The 23Ah-specific table in the ONYX owner manual, page 44 , identifies Panasonic NCR18650PF 2900mAh cells and a 20S8P pack. The earlier Samsung 25R entry in this blog was incorrect. Another general table in that manual differs on parallel count, so match the battery-specific table and actual pack identification. A voltage chart alone cannot establish cell identity.

Battery and Cell Voltage Chart

The amount of time a battery cell stays above 4.2V or below 2.5V is critical. A few seconds might be tolerable, but staying in those ranges for minutes or hours significantly increases the risk of thermal runaway above 4.2V or permanent cell damage below 2.5V.

Cell VoltsDescription
4.50vThermal Runaway Risk
4.45vThermal Runaway Risk
4.40vThermal Runaway Risk
4.35vThermal Runaway Risk
4.30vThermal Runaway Risk
4.25vOvercharge / Degradation
4.20v100% (Full Charge)
4.15vNear Full (Common BMS Limit)
4.10v
4.05v
4.00vHigh State of Charge
3.95v
3.90v~75%
3.85v
3.80v
3.75v
3.70vNominal Voltage
3.65vNominal Voltage
3.625v~50%
3.60v
3.55v
3.50v
3.45v
3.40v
3.35v
3.30v~25%
3.25v
3.20v
3.15v
3.10v
3.05v
3.00vTypical Cutoff (Not True 0%)
2.95v
2.90v
2.85v
2.80v
2.75v
2.70vDeep Discharge (Cell Stress)
2.65v
2.60v
2.55v
2.50vMinimum (Damage Threshold)

This chart is best used as a reference guide. Resting voltage, loaded voltage, BMS tuning, and battery chemistry can shift where these thresholds appear in real-world use.


Battery Operating Range

PlatformFull VoltageEmpty VoltageStorage VoltageMax Regen
72V83-84 V60 V72-79 V40 A

Empty voltage and regen behavior vary under load, temperature, and controller settings. These values are best treated as reference ranges, not fixed under-throttle readings.


ONYX 45Ah 72V Reading Battery Level

VoltageState
84 VFull
72 V~50%
60 VEmpty

ONYX 45Ah 72V Battery and Cell Voltage Chart

Battery VCell VDescription
90V4.50VThermal runaway risk
88V4.40VThermal runaway risk
85V4.25VRapid degradation
84V4.20VTrue 100%
83V4.15VStock “100%”
80V4.00V~80%
74V3.70VStorage level
72.5V3.63V~50%
66V3.30V~25%
60V3.00VEmpty
50V2.50VMinimum
<50V<2.50VDamage occurs

ONYX 41Ah 72V Voltage vs Usability

  • 84-80V

    • strong output
    • rapid initial drop
  • 80-72V

    • most stable range
    • best efficiency
  • below ~66V

    • high sag
    • reduced power
    • increased cutoff risk

ONYX 41Ah 72V Discharge Behavior

High State (83V-80V)

  • strong output
  • noticeable sag

Mid Range (80V-72V)

  • most stable
  • best efficiency

Low Range (<66V)

  • increased sag
  • reduced power
  • cutoff risk

ONYX 41Ah 72V Discharge Curve

  • 8% -> 62V
  • 4% -> 61V
  • 0% -> 60V

ONYX RCR voltage discharge curve