This post serves as a hands-on technical guide for the 80V ONYX platform.
It brings together:
- Real-world performance data
- Battery and controller operating boundaries
- Vehicle weight, tire specs, and electrical characteristics
- IP ratings for water and dust resistance
- Safe temperature ranges for the motor, battery, and controller
The article begins with a concise overview and then transitions into full technical specifications and advanced thermal considerations for high-power riding.
| Mode | kW | HP |
|---|
| Normal Mode | 8 | 10.7 |
| Sports Mode | 18 | 24.1 |
| Hyper Mode | 22 | 29.5 |
Temperature Limits#
| Component | Max |
|---|
| Controller | 212°F |
| Motor | 338°F |
| Battery | 160°F (BMS cutoff ~140°F) |
Weight & Load#
| Item | Value |
|---|
| Bike | 150 lb |
| Bike without battery | 115 lb |
| 45Ah battery | 35 lb |
| Max load | 385 lb |
| Rear rack | 45 lb |
Dimensions#
| Bike | Long | Wide | Tall STD | Tall STY |
|---|
| ONYX 80V | 69" (5.75') | 27" (2.25') | 40" (3.33') | 38" (3.17') |
| Seat | Value |
|---|
| Seat Size | 19" long × 7" wide × 4" high |
| Seat Foam Thickness | 2" |
| Seating Length | 16" |
| Standard Seat Height | 33" |
| Shorty Seat Height | 31.5" |
| Tire | Value |
|---|
| Tire Diameter | 23" front / rear |
Materials#
| Item | Value |
|---|
| Bike frame | Aluminum 6082-T6 |
| Rear swing arm | Aluminum 6082-T6 |
| 45Ah battery case | Aluminum 6061-T6 |
| Handlebars | Aluminum 6061-T6 |
| Front forks | Aluminum 7005-T6 |
| Rear suspension | Steel 1020 / 1026 DOM |
| Rear rack | Aluminum 6061-T6 |
Tires#
| Item | Value |
|---|
| Pressure | 32-35 PSI |
| Tube | Tubless |
Battery Operating Range#
| Item | Value |
|---|
| Full voltage | 91-92 V |
| Empty voltage | 66 V |
| Storage voltage | 80-87 V |
| Charge temperature | <105°F |
| Max regen | 40 A |
| Charge connector | HIGO S824B / QS9 Adapter 14 AWG |
| Discharge connector | QS9 6 AWG |
Battery Specifications#
| Battery | Voltage | Continuous | Peak / Pulse |
|---|
| ONYX 45Ah | 80V | 120 A | 200 A |
- Peak: 0.5 to 5 seconds
- Pulse: 5 to 30 seconds
Cell Specifications#
| Pack | Cell | Chemistry | Cycles |
|---|
| 45Ah | Tenpower 50SG | NCA | ~700 |
Controller Summary#
| Item | Value |
|---|
| Stock tune | Eco 750 W / Normal 6kW / Sport 18kW / Hyper 22kW |
| 0-30 mph | ~1.7 s |
Headlight Wires#
| Bike Wires | Designation | Notes |
|---|
| Black | Negative | |
| Red | Day Time | Always on 12v |
| Yellow | Low Beam | |
| Blue | High Beam | |
Taillight Wires#
| Bike Wires | Designation | Notes |
|---|
| Black | Negative | |
| Blue | Taillight dim | Always on 12v |
| Red | Taillight brighter | |
Brake Disc Measurements#
| Part | Measurements |
|---|
| Rear Disc | 220 mm × 3 mm, PCD: 6×44 mm, CB: 32 mm |
A 220 mm brake disc is 220 mm across and 3 mm thick. A PCD of 6×44 mm means it uses six bolts arranged on a 44 mm circle and must match your hub. A 32 mm center bore is the size of the hole in the middle that centers the disc on the hub.
Ratings#
Battery#
| Year | Model | IP | Impact |
|---|
| 202 | 45Ah | 55 | C4 |
Motor#
| Years | Model | IP |
|---|
| 2025-2026 | 80V Custom Motor | 65 |
Controller#
| Years | Model | IP |
|---|
| 2025-2026 | 80V Custom Controller | 67 |
Display#
| Years | Part | IP |
|---|
| 2025-2026 | Color Touch Display | 67 |
Temperatures#
This section lists the safe operating temperature ranges for the main 80V components, including the battery, controller, and motor.
Fahrenheit#
| Component | Good | Okay | High |
|---|
| Motor | 120°F | 150°F | 248°F |
| Controller | 110°F | 130°F | 176°F |
| Battery | 90°F | 100°F | 130°F |
Celsius#
| Component | Good | Okay | High |
|---|
| Motor | 48°C | 65°C | 120°C |
| Controller | 43°C | 54°C | 80°C |
| Battery | 32°C | 37°C | 54°C |
Motor Temperature#
ONYX hub motors use NdFeB neodymium magnets.
Key thresholds:
- 120°C / 248°F -> ideal sustained ceiling
- 150°C / 302°F -> caution zone
- 180°C+ / 356°F -> insulation + magnet damage risk
- 200°C+ / 392°F -> permanent demagnetization likely
Magnet Loss Reference#
| Condition | °C | °F |
|---|
| Cutoff | 170 | 338 |
| Caution | 150 | 302 |
| High | 120 | 248 |
| Okay | 90 | 194 |
| Good | 60 | 140 |
Battery Temperature#
Best practice:
- Charge and store between 50°F-86°F (10°C-30°C)
Cold reduces range. Heat accelerates aging.
| Condition | °C | °F |
|---|
| Cutoff | 60 | 140 |
| High | 54 | 130 |
| Okay | 43 | 110 |
| Good | 25 | 77 |
| Minimum | 0 | 32 |
Do not store below 32°F for more than a few hours.
Controller Temperature#
Controller heat is easiest to manage with airflow.
| Condition | °C | °F |
|---|
| Cutoff | 100 | 212 |
| High | 80 | 176 |
| Okay | 70 | 158 |
| Good | 50 | 122 |
Final Advice#
Run smart with your voltage.
Stay within safe temperature ranges.
Keep an eye on motor temps when pushing higher current.
Only charge batteries when they’re cool.
And don’t forget:
Water-resistant doesn’t mean waterproof.
A cool ONYX is a quick ONYX, and one that lasts. ⚡