ONYX 41AH BMS BMS Settings

Use the Overkill Solar BMS app or Xiaoxiang BMS app to tune the ONYX 41Ah battery. In the configuration screens, adjust the following fields for optimal performance:

  • Total Battery Capacity: Set this field to the full capacity of the battery in milliamp-hours (mAh). For a 41Ah battery, this value would be 41000.
  • Total Cycle Capacity: Set this field to 80% of the total capacity. For a 41Ah battery, this value would be 32800.
  • These settings can be applied to all battery configurations.
  • Total Battery Capacity 100%
  • Total Cycle Capacity 80%

BMS Stock Configuration

Capacity Configuration

  • Number of Cell - 20
  • Total Battery Capacity - 41000
  • Total Cycle Capacity - 32800
  • Cell Full Voltage - 4150
  • Cell Minimum Voltage - 3000
  • Cell Self Discharge - 0.2
  • Cell 80% Cap. Voltage - 4000
  • Cell 60% Cap. Voltage - 3800
  • Cell 40% Cap. Voltage - 3600
  • Cell 20% Cap. Voltage - 3300

Balancer Configuration

  • Start Voltage - ​4000
  • Delta to Balance - 15
  • Balancer Enabled - On (Green)
  • Bal. Only When Charging - On (Green)

Function Configuration

  • Switch - Off

Protections

T: = Trigger Value / R: = Release Value

  • Cell Over Voltage - T: 4250 / R: 4150
  • Cell Under Voltage - T: 2700 / R: 3000
  • Batt Over Volt. - T: 85000 / R: 83000
  • Batt Under Volt. - T: 54000 / R: 60000
  • Charge Over Curr. - T: 70000 / R: 32
  • (80 Amp BMS) Discharge Over Curr. - T: 90000 / R: 32
  • (100 Amp BMS) Discharge Over Curr. - T: 110000 / R: 32
  • Charge Over Temp - T: 65 / R: 55
  • Charge Under Temp - T: -5 / R: 0
  • Discharge Over Temp - T: 70 / R: 60
  • Discharge Under Temp - T: -10 / R: 0

ONYX 41AH Battery Tuning

This screenshot shows an ONYX 41Ah battery calibrated to around 60 volts, with an additional 5Ah of capacity remaining. This extra capacity extends the range by 4 to 10 miles, depending on throttle use. For full-throttle riding, the added 5Ah provides approximately 3 extra miles of high-speed performance at the top of the charge.

regular

Tuned BMS Resting Voltage

When optimizing the BMS for enhanced performance and range, it’s essential to consider the significance of resting voltage levels to maintain battery health and longevity.

BMS Tuned Configuration

Capacity Configuration

  • Number of Cell - 20
  • Total Battery Capacity - 41000
  • Total Cycle Capacity - 32800
  • Cell Full Voltage - 4150
  • Cell Minimum Voltage - 2700
  • Cell Self Discharge - 0.2
  • Cell 80% Cap. Voltage - 3950
  • Cell 60% Cap. Voltage - 3700
  • Cell 40% Cap. Voltage - 3400
  • Cell 20% Cap. Voltage - 3100

Balancer Configuration

  • Start Voltage - 3800
  • Delta to Balance - 10
  • Balancer Enabled - On (Green)
  • Bal. Only When Charging - On (Green)

Function Configuration

  • Switch - Off

Protections

T: = Trigger Value / R: = Release Value

  • Cell Over Voltage - T: 4200 / R: 4100
  • Cell Under Voltage - T: 2600 / R: 2800
  • Batt Over Volt. - T: 85000 / R: 83000
  • Batt Under Volt. - T: 53000 / R: 59000
  • Charge Over Curr. - T: 70000 / R: 32
  • (80 Amp BMS) Discharge Over Curr. - T: 90000 / R: 32
  • (100 Amp BMS) Discharge Over Curr. - T: 110000 / R: 32
  • Charge Over Temp - T: 65 / R: 55
  • Charge Under Temp - T: -5 / R: 0
  • Discharge Over Temp - T: 70 / R: 60
  • Discharge Under Temp - T: -10 / R: 0