This is a separately labeled background reference for the blog’s Kelly firmware-dependent and non-exposed parameter discussion. It is not a stock ONYX settings article or confirmation that these fields exist on a specific controller.
Evidence and Programming Boundary
The recorded ONYX KLS7230S stock export identifies its own controller/firmware. The representative fields, ranges, conceptual control loops, and hidden features below have not been established by that export. Blank values remain blank. Statements about typical defaults or enabled behavior are source examples, not verified instructions for the reader’s controller.
Kelly publishes manuals for KLS-S and KLS-N families separately. A family-level manual or an example from another revision does not verify every field in this cross-variant list. Use the exact model, firmware, and exposed configuration interface when deciding what is available. Do not infer sensorless fallback, field weakening, PID access, or any other feature from this article alone.
For the observed ONYX parameter relationships and programming workflow, see Kelly Controller Parameters and Behavior . This article preserves the explanatory material without converting it into an authoritative tuning recipe.
Additional Firmware / Hidden Parameters (Reference Table)
This table is a reference index of firmware-dependent and non-exposed parameters that may exist across Kelly variants. Detailed behavior, example ranges, and interaction notes are documented in the sections that follow.
| Field | Value | Notes |
|---|---|---|
| Min Excitation | Lower bound of field weakening behavior | |
| Max Excitation | Upper excitation limit before weakening transitions | |
| Field Weakening Enable | Typically enabled in performance configurations | |
| Flux Weakening % | Controls strength of high-speed field reduction | |
| Max Regen Current | Primary limiter of regen strength | |
| Regen Current Limit | Caps regen regardless of brake % | |
| EBS Level | Firmware-dependent regen scaling | |
| Torque Limit | Internal torque ceiling | |
| Max Torque Command | Limits requested torque before output stage | |
| Absolute Speed Limit | Hard RPM ceiling independent of throttle | |
| Bus Voltage Compensation | Increases current to offset voltage sag | |
| Power Limit vs Voltage | Reduces output as voltage drops | |
| Torque Mode / Speed Mode | Typically torque mode for vehicle applications | |
| Regen Enable Modes | Determines when regen is allowed to engage | |
| Direction Change Protection | Typically enabled to prevent unsafe reversal under load | |
| Brk_Speed Limit | 100 RPM | Minimum RPM where regen becomes effective |
| Low Speed Regen Cutoff | Further reduces regen near zero speed | |
| Regen Ramp Rate | Controls how quickly regen torque builds | |
| Regen Voltage Clamp | Limits regen near overvoltage threshold | |
| Regen Current Slew Limit | Smooths regen current transitions | |
| High Temp Str C | Start of thermal derating (below 170°C cutoff) | |
| High Temp Weak % | Strength of thermal derating | |
| Thermal Derating Slope | Rate of power reduction with temperature | |
| Thermal Foldback Gain | Aggressiveness of thermal limiting | |
| Thermal Recovery Rate | Speed of power restoration after cooling | |
| Max Torque Clamp | Hard internal torque ceiling | |
| Torque Limit vs Speed Curve | Reduces torque as RPM increases | |
| Torque Derate vs RPM | High-speed torque reduction behavior | |
| Electrical Frequency Clamp | Limits max electrical output frequency | |
| Back EMF Compensation | Adjusts output at high speed | |
| Field Weakening Ramp Rate | Speed of weakening engagement | |
| Hall Sequence Validation | Prevents invalid hall transitions (typically enabled) | |
| Phase Alignment Offset | Fine adjustment of commutation timing | |
| Auto-Identification State Machine | Runs during motor identification (startup or triggered) | |
| Phase Advance Angle (Dynamic) | Increases with RPM for efficiency | |
| Commutation Advance Map | Speed-based timing adjustment | |
| Dynamic Current Limiting vs Voltage | Reduces output during voltage sag | |
| DC Bus Ripple Filter | Smooths voltage fluctuations | |
| DC Bus Voltage Averaging Window | Response speed to voltage changes | |
| Precharge Detection Threshold | Typically ~60-90% of pack voltage | |
| Precharge Timeout | Prevents failed startup condition | |
| Contactor Delay Control | Controls engagement timing | |
| Reverse Torque Limit | Typically reduced vs forward torque | |
| Reverse Speed Clamp | Limits reverse speed | |
| Direction Change Lockout Timer | Prevents immediate reversal | |
| Direction Change Delay Timer | Adds delay before torque reapply | |
| Torque Command Filter | Smooths throttle-to-torque response | |
| Current Slew Rate Limit | Limits current rise/fall speed | |
| Current Loop Saturation Limit | Caps internal current demand | |
| Iq/Id Decoupling Gain | Improves FOC control separation | |
| Speed Loop Output Clamp | Limits speed loop authority | |
| Speed Loop Integral Limit | Prevents integral wind-up | |
| Flux Observer Gain | Rotor estimation responsiveness | |
| Rotor Observer Filter Constant | Smooths rotor position estimation | |
| Deadtime Compensation | Corrects switching delay losses | |
| PWM Deadtime | Prevents transistor shoot-through | |
| MOSFET Thermal Model | Internal temperature estimation (typically enabled in firmware) | |
| Stall Detection Threshold | Detects non-rotating motor under load | |
| Stall Current Limit | Limits current during stall | |
| Anti-Stall Recovery Timer | Delay before retry | |
| Slip Detection Threshold | Detects mismatch in expected speed | |
| Slip Compensation Gain | Adjusts torque during slip | |
| Overvoltage Regen Suppression | Typically enabled to protect battery from overvoltage | |
| Regen Disable on Fault Flag | Commonly enabled to disable regen during fault conditions | |
| Fault Latch Behavior | Latched | Requires reset after fault |
| Fault Auto-Recovery Enable | Allows automatic recovery | |
| Watchdog Timer | Firmware safety reset timer | |
| Startup Torque Boost (Internal) | Improves launch from stop | |
| Startup Alignment Current | Holds rotor before movement | |
| Startup Alignment Time | Duration of alignment phase | |
| Zero Speed Lock Detection | Typically enabled to detect stopped motor state | |
| Neutral State Current Clamp | Prevents unintended movement | |
| Hall Signal Debounce Time | Filters noisy hall signals | |
| Hall Error Timeout | Detects signal loss | |
| Encoder Signal Loss Timeout | Detects encoder failure | |
| Resolver Signal Quality Threshold | Minimum valid signal level | |
| Sensorless Transition Threshold | RPM where fallback may occur | |
| Sensorless Fallback Enable | Allows operation without sensors (firmware-dependent) | |
| Throttle Plausibility Check | Typically enabled to prevent invalid throttle input | |
| Brake-Throttle Override Logic | Commonly enabled so brake input overrides throttle | |
| CAN Timeout Threshold | Detects communication loss | |
| Communication Loss Fallback Mode | Defines behavior when communication is lost (disable / limp / coast) | |
| ID Err | Diagnostic flag for identification failure |
Additional Parameters (Firmware Dependent)
This section lists firmware-dependent parameters that may exist on other Kelly variants but are not visible in this dataset.
The Kelly KLS7230S controller may expose additional parameters depending on firmware version, controller revision, and configuration software. These are not present in this dataset but may appear in other controller variants.
Their absence in the table does not indicate missing functionality.
These parameters are often controlled internally by firmware, may not be visible or adjustable through standard Kelly configuration tools, and follow the same system relationships defined above. They may also override or interact with user-visible settings in the main configuration table.
Field Weakening
| Parameter | Example Value / Range | What It Does |
|---|---|---|
| Min Excitation | 5-15% | Sets the lower excitation floor used when weakening begins |
| Max Excitation | 80-100% | Sets the upper excitation limit available before weakening behavior changes |
| Field Weakening Enable | On / Off | Enables or disables field weakening behavior |
| Flux Weakening % | 5-20% mild, 20-40% aggressive | Controls how strongly the controller reduces effective field strength at high RPM |
These parameters control high-speed operation beyond the motor’s normal voltage-limited speed range.
- field weakening allows the motor to spin faster than its normal base speed at a given battery voltage
- it works by reducing effective magnetic field strength at higher RPM
- this increases top-end speed, but it does not create additional power
Behavior characteristics:
- low values produce a mild top-speed increase with less heat
- higher values can extend speed further, but current draw rises quickly
- torque drops off more noticeably as speed increases
- motor and controller temperature climb faster during sustained high-speed riding
Important:
- field weakening does not increase total power, only extends usable RPM range
- aggressive values can overheat the motor quickly
- excessive weakening can make the bike feel faster at the top end but weaker and less efficient under load
- real results depend heavily on battery voltage, gearing, motor characteristics, and load
Regenerative Braking Control
| Parameter | Example Value / Range | What It Does |
|---|---|---|
| Max Regen Current | 10-30A mild, 30-60A strong | Sets the upper limit for how much regen current the controller can send back into the battery |
| Regen Current Limit | 10-50A | Caps regen output regardless of brake percentage settings |
| EBS Level | 1-3 light, 4-6 medium, 7-10 aggressive | Sets the overall strength of electronic braking behavior, depending on firmware scale |
These fields determine how much regenerative current the controller is actually allowed to apply.
- these fields control how much braking force the controller can produce electrically
- unlike brake percentage settings, they act as current-based limits on how much regen can actually happen
- this is a primary factor in whether regen feels light, moderate, or very strong when the brake is applied
Behavior characteristics:
- lower values produce gentler deceleration and less battery charging current
- higher values increase braking force and make regen more noticeable
- aggressive settings can make the bike feel abrupt when braking begins
- regen is strongest at higher speed and naturally gets weaker as RPM drops
Important:
- these limits may override or reshape BRK_SW / BRK_AD percentage settings
- actual regen feel is usually a combination of brake percentage, regen current limits, and motor speed
- excessive values can increase battery stress, BMS intervention, and motor heat during repeated braking
- strong regen settings may feel good at speed but still taper off near low RPM because back EMF falls with speed
Torque and Speed Limits
| Parameter | Example Value / Range | What It Does |
|---|---|---|
| Torque Limit | Example range: 60-100% typical, 100%+ less restricted | Caps maximum motor torque output |
| Max Torque Command | Example range: 50-100% | Limits how much torque the controller will request internally |
| Absolute Speed Limit | Example range: 12000-18000 RPM | Sets a hard ceiling on motor speed regardless of throttle input |
These fields act as hard limits on what the controller is allowed to output.
- these parameters act as upper limits on what the controller is allowed to do
- they apply regardless of throttle position or rider input
- they sit above other settings like throttle mapping and current limits
Behavior characteristics:
- lower torque limits reduce acceleration and overall power feel
- increasing torque limits improves launch and responsiveness
- speed limits cap top speed even if the system has power to go faster
- aggressive limits can make the bike feel unrestricted but increase system stress
Important:
- these limits may override phase current and throttle mapping behavior
- setting torque too low can make the bike feel flat or unresponsive
- setting speed limits too low can prevent reaching expected top speed even with correct gearing and power
- these are often used for safety, battery protection, or drivetrain longevity
Voltage Compensation
| Parameter | Example Value / Range | What It Does |
|---|---|---|
| Bus Voltage Compensation | 0-10% mild, 10-25% aggressive | Adjusts output to compensate for voltage sag under load |
| Power Limit vs Voltage | Linear or stepped curve | Reduces available power as battery voltage drops |
These parameters control how the controller responds to battery voltage sag during load.
- these parameters adjust how aggressively the controller tries to maintain performance as voltage drops
- instead of letting power fall naturally with voltage, compensation increases current draw to hold output
Behavior characteristics:
- low compensation results in noticeable power drop as battery voltage sags
- higher compensation keeps acceleration and power more consistent under load
- aggressive settings increase current draw to maintain output
- system may feel strong even at lower battery voltage, but at the cost of efficiency
Important:
- higher compensation increases battery stress and heat
- interacts directly with Bat Current Limit and overall system power draw
- aggressive settings can increase voltage sag rather than reduce it under heavy load
- behavior depends heavily on battery condition, internal resistance, and discharge capability
Control Mode and Behavior Flags
| Parameter | Example Value / Range | What It Does |
|---|---|---|
| Torque Mode / Speed Mode | Torque (default), Speed (less common) | Determines whether throttle controls torque output or targets a speed |
| Regen Enable Modes | Off / Throttle Release / Brake Only / Combined | Defines when regenerative braking is allowed to engage |
| Direction Change Protection | Enabled / Disabled | Prevents unsafe direction changes while the motor is still rotating |
These fields control the controller’s internal operating modes and logic behavior.
- these parameters control how the controller interprets inputs and applies output
- they change the overall behavior of throttle, braking, and direction handling
- unlike tuning values, these act more like system-level switches
Behavior characteristics:
- torque mode provides direct and predictable throttle response based on rider input
- speed mode attempts to maintain a target speed, which can feel less natural on a bike
- regen modes determine whether braking occurs on throttle release, brake input, or both
- direction protection prevents immediate reversal, reducing drivetrain shock
Important:
- typically firmware-controlled and not always exposed in user tools
- incorrect mode selection can make throttle response feel unnatural or unstable
- regen mode configuration can significantly change how the bike behaves when coasting or braking
- direction protection is critical for safety and preventing mechanical damage
Additional Parameters (Extended Firmware Variants)
This section covers parameter families that may be user-visible in some Kelly firmware branches, engineering tools, or controller revisions, but are not present in this dataset.
The Kelly KLS7230S controller may expose additional parameters in other firmware branches, engineering tools, or controller revisions. These are not present in this dataset but are consistent with behavior seen across Kelly KLS variants.
Their absence in the table does not indicate lack of functionality.
These fields may be user-visible in some firmware, hidden in others, or partially controlled through internal logic that sits on top of the exposed parameter set.
Regenerative Behavior (Extended)
| Parameter | Example Value / Range | What It Does |
|---|---|---|
| Brk_Speed Limit | 100 RPM | Minimum motor speed at which regenerative braking becomes active |
| Low Speed Regen Cutoff | Example range: 0-100 RPM below active regen region | Further tapers or disables regen as speed approaches zero |
| Regen Ramp Rate | Slow / Medium / Fast | Controls how quickly regen torque is applied |
| Regen Voltage Clamp | Near pack overvoltage threshold | Limits regen current as battery voltage approaches protection limit |
| Regen Current Slew Limit | Low / Medium / High or firmware-dependent ramp rate | Limits how quickly regen current can rise or fall |
These parameters extend regenerative braking behavior beyond the standard exposed brake percentage and timing fields.
- Brk_Speed Limit defines the minimum motor speed (RPM) at which regenerative braking becomes active
- below this RPM, regen is reduced or effectively disabled because back EMF is too low to push current into the battery
- this is the point where regen begins to engage and become usable
- Low Speed Regen Cutoff defines an additional region where regen may be further limited or tapered as speed approaches zero
- Regen Ramp Rate and Regen Current Slew Limit shape how quickly braking torque is applied and removed
- Regen Voltage Clamp limits regenerative current as battery voltage approaches overvoltage protection
Behavior characteristics:
- regen strength drops as speed approaches the Brk_Speed Limit threshold
- below ~100 RPM, braking typically transitions from electrical regen to primarily mechanical braking
- prevents unstable or jerky braking at very low speed
- smooths braking engagement and release
- prevents abrupt negative torque spikes
- reduces the chance of overvoltage faulting during high-speed deceleration
Important:
- may not appear in standard Kelly tools
- may override or reshape BRK_SW / BRK_AD behavior
- real regen feel is determined by both exposed settings and internal limits like Brk_Speed Limit
Thermal Management (Extended)
| Parameter | Example Value / Range | What It Does |
|---|---|---|
| High Temp Str C | Typical example range: 120-150°C | Temperature where the controller starts reducing output |
| High Temp Weak % | Low / Medium / High or firmware-dependent scaling | Controls how aggressively power is reduced once thermal limiting starts |
| Thermal Derating Slope | Shallow / Medium / Steep | Controls how quickly output falls as temperature rises |
| Thermal Foldback Gain | Low / Medium / High | Shapes how strongly the controller folds power back under heat |
| Thermal Recovery Rate | Slow / Medium / Fast | Controls how smoothly power returns after cooling |
These parameters control how the controller reduces power as temperatures rise, before reaching full shutdown.
- High Temp Str C defines the temperature where the controller starts reducing output
- this is the point where power begins to get pulled back to prevent overheating
- on most systems, this occurs noticeably before the hard cutoff (High Temp Cut C = 170°C in this case)
- High Temp Weak % defines how aggressively power is reduced once thermal limiting starts
- lower values result in gradual power reduction, higher values cause faster and stronger derating
- Thermal Derating Slope, Thermal Foldback Gain, and Thermal Recovery Rate control how quickly power is reduced and how smoothly it returns after cooling
Behavior characteristics:
- power is reduced gradually before reaching the shutdown temperature
- under sustained load, output will continue to drop as temperature increases
- repeated hard acceleration or high-speed riding will trigger earlier and stronger derating
- power does not immediately return once temperatures drop; recovery is controlled and delayed
- depending on settings, the system may feel strong initially but fade quickly under continuous load
Important:
- not exposed in this dataset
- works together with High Temp Cut C (170°C) and High Temp Resume (150°C)
- High Temp Str C typically sits well below the cutoff to allow controlled derating instead of abrupt shutdown
- has a major impact on how much power the system can sustain over time
- this is one of the main reasons short bursts feel strong, but continuous riding feels weaker as heat builds
Torque and Speed Constraints (Extended)
| Parameter | Example Value / Range | What It Does |
|---|---|---|
| Max Torque Clamp | Example range: 80-120% | Sets an internal hard ceiling on torque output regardless of other limits |
| Torque Limit vs Speed Curve | Linear / stepped reduction | Reduces available torque as speed increases |
| Torque Derate vs RPM | Starts ~60-80% of max RPM | Gradually lowers torque at higher motor speeds |
| Electrical Frequency Clamp | Example range: 800-1200 Hz, firmware-dependent | Caps maximum electrical output frequency |
| Back EMF Compensation | 0-20% | Adjusts output to account for increasing back EMF at high speed |
| Field Weakening Ramp Rate | Slow / Medium / Fast | Controls how quickly field weakening is applied as speed increases |
These fields shape deeper torque and speed limits that are not always visible in the standard UI.
- these parameters shape how torque is delivered across the full speed range
- they control the transition from strong low-speed acceleration to limited high-speed output
- they operate on top of visible limits like Max Speed and Phase Current
Behavior characteristics:
- strong torque at low speed gradually fades as RPM increases
- prevents excessive current draw at high speed where efficiency drops
- smooths the transition into top-speed operation
- limits abrupt or unstable behavior near maximum speed
- affects how aggressively field weakening engages at higher RPM
Important:
- may appear only in certain firmware or controller variants
- may override visible speed or current settings even when those values appear unchanged
- top-speed behavior is often governed more by these parameters than by Max Speed alone
- overly aggressive limits can make the bike feel strong off the line but weak at speed
- overly loose limits can increase heat, instability, and system stress at high RPM
Sensor and Identification Extensions
| Parameter | Example Value / Range | What It Does |
|---|---|---|
| Hall Sequence Validation | Enabled / Disabled | Verifies correct hall sensor transition order |
| Phase Alignment Offset | ±0-10° electrical | Applies correction to align controller output with motor position |
| Auto-Identification State Machine | Run on startup / manual trigger | Handles automated motor identification and calibration |
| Phase Advance Angle (Dynamic) | 0-20° increasing with RPM | Advances timing as speed increases for efficiency |
| Commutation Advance Map | Speed-based curve | Defines how phase advance changes across RPM range |
These parameters control additional motor identification and commutation behavior beyond the visible sensor setup fields.
- these parameters control how the controller understands rotor position and aligns electrical output with the motor
- they refine timing, improve efficiency, and ensure correct commutation across all speeds
- they operate continuously in the background once the system is running
Behavior characteristics:
- correct values result in smooth operation and consistent torque delivery
- phase advance improves efficiency and reduces heating at higher speeds
- improper alignment can cause rough operation, noise, or reduced performance
- identification routines ensure the controller matches the specific motor characteristics
Important:
- may be partially exposed only through engineering or OEM tools
- directly tied to motor identification success and sensor configuration
- incorrect hall sequence or phase alignment can prevent operation or trigger faults
- errors in this layer often appear as hard faults or startup failure rather than simple tuning issues
Voltage and Startup Management (Extended)
| Parameter | Example Value / Range | What It Does |
|---|---|---|
| Dynamic Current Limiting vs Voltage | 0-30% scaling | Reduces output as battery voltage drops under load |
| Power Limiting Curve | Linear / stepped curve | Defines how available power changes across voltage range |
| DC Bus Ripple Filter | Low / Medium / High filtering | Smooths rapid voltage fluctuations from the battery |
| DC Bus Voltage Averaging Window | 10-100 ms | Determines how quickly voltage changes affect control decisions |
| Precharge Detection Threshold | ~60-90% of pack voltage | Detects when safe precharge voltage is reached before enabling full power |
| Precharge Timeout | 100-1000 ms | Sets how long the controller waits for precharge before faulting |
| Contactor Delay Control | 50-500 ms | Delays full engagement to protect components during startup |
These parameters control higher-level power and startup management behavior.
- these parameters control how the controller reacts to unstable or changing battery voltage
- they also manage how the controller safely powers on and connects to the battery
- they operate continuously during both startup and riding conditions
Behavior characteristics:
- smooths power delivery during voltage sag or heavy load
- reduces sudden drops or spikes in output caused by battery instability
- prevents damaging current spikes during controller startup
- affects how quickly the controller responds to voltage changes under load
Important:
- may be hidden in standard user tools
- directly interacts with Low Volt, Over Volt, and Bat Current Limit
- aggressive current limiting can make the bike feel weak under load
- insufficient filtering or delay can cause harsh startup behavior or fault conditions
- startup reliability and consistency are heavily influenced by these parameters
Reverse and Direction Control (Extended)
| Parameter | Example Value / Range | What It Does |
|---|---|---|
| Reverse Torque Limit | 20-50% typical | Limits available torque when operating in reverse |
| Reverse Speed Clamp | 20-50% of forward speed | Caps maximum reverse speed |
| Direction Change Lockout Timer | 200-1000 ms | Prevents immediate direction changes while motor is still spinning |
| Direction Change Delay Timer | 100-500 ms | Adds a delay before applying torque after a direction change |
These parameters control additional reverse and direction change behavior.
- these parameters control how the system behaves when switching between forward and reverse
- they are primarily designed to protect the drivetrain and improve rideability
- they operate automatically whenever a direction change is requested
Behavior characteristics:
- reverse power is usually reduced to prevent abrupt or unsafe movement
- reverse speed is limited compared to forward operation
- direction changes are delayed to allow the motor to slow down before reversing
- prevents sudden torque reversal that can stress mechanical components
Important:
- may be hidden even when Change Dir is exposed in the main settings
- intended primarily for safety and hardware protection
- aggressive or disabled limits can cause harsh or damaging direction changes
- overly restrictive values can make reverse feel weak or unresponsive
- timing behavior can make direction changes feel delayed if not understood
Internal / Non-Exposed Control Parameters
See Kelly: Internal Control Behavior for this reference.
