This is a separately labeled background reference for the blog’s Kelly firmware-dependent and non-exposed parameter discussion. It is not a stock ONYX settings article or confirmation that these fields exist on a specific controller.

Evidence and Programming Boundary

The recorded ONYX KLS7230S stock export identifies its own controller/firmware. The representative fields, ranges, conceptual control loops, and hidden features below have not been established by that export. Blank values remain blank. Statements about typical defaults or enabled behavior are source examples, not verified instructions for the reader’s controller.

Kelly publishes manuals for KLS-S and KLS-N families separately. A family-level manual or an example from another revision does not verify every field in this cross-variant list. Use the exact model, firmware, and exposed configuration interface when deciding what is available. Do not infer sensorless fallback, field weakening, PID access, or any other feature from this article alone.

For the observed ONYX parameter relationships and programming workflow, see Kelly Controller Parameters and Behavior . This article preserves the explanatory material without converting it into an authoritative tuning recipe.

Additional Firmware / Hidden Parameters (Reference Table)

This table is a reference index of firmware-dependent and non-exposed parameters that may exist across Kelly variants. Detailed behavior, example ranges, and interaction notes are documented in the sections that follow.

FieldValueNotes
Min ExcitationLower bound of field weakening behavior
Max ExcitationUpper excitation limit before weakening transitions
Field Weakening EnableTypically enabled in performance configurations
Flux Weakening %Controls strength of high-speed field reduction
Max Regen CurrentPrimary limiter of regen strength
Regen Current LimitCaps regen regardless of brake %
EBS LevelFirmware-dependent regen scaling
Torque LimitInternal torque ceiling
Max Torque CommandLimits requested torque before output stage
Absolute Speed LimitHard RPM ceiling independent of throttle
Bus Voltage CompensationIncreases current to offset voltage sag
Power Limit vs VoltageReduces output as voltage drops
Torque Mode / Speed ModeTypically torque mode for vehicle applications
Regen Enable ModesDetermines when regen is allowed to engage
Direction Change ProtectionTypically enabled to prevent unsafe reversal under load
Brk_Speed Limit100 RPMMinimum RPM where regen becomes effective
Low Speed Regen CutoffFurther reduces regen near zero speed
Regen Ramp RateControls how quickly regen torque builds
Regen Voltage ClampLimits regen near overvoltage threshold
Regen Current Slew LimitSmooths regen current transitions
High Temp Str CStart of thermal derating (below 170°C cutoff)
High Temp Weak %Strength of thermal derating
Thermal Derating SlopeRate of power reduction with temperature
Thermal Foldback GainAggressiveness of thermal limiting
Thermal Recovery RateSpeed of power restoration after cooling
Max Torque ClampHard internal torque ceiling
Torque Limit vs Speed CurveReduces torque as RPM increases
Torque Derate vs RPMHigh-speed torque reduction behavior
Electrical Frequency ClampLimits max electrical output frequency
Back EMF CompensationAdjusts output at high speed
Field Weakening Ramp RateSpeed of weakening engagement
Hall Sequence ValidationPrevents invalid hall transitions (typically enabled)
Phase Alignment OffsetFine adjustment of commutation timing
Auto-Identification State MachineRuns during motor identification (startup or triggered)
Phase Advance Angle (Dynamic)Increases with RPM for efficiency
Commutation Advance MapSpeed-based timing adjustment
Dynamic Current Limiting vs VoltageReduces output during voltage sag
DC Bus Ripple FilterSmooths voltage fluctuations
DC Bus Voltage Averaging WindowResponse speed to voltage changes
Precharge Detection ThresholdTypically ~60-90% of pack voltage
Precharge TimeoutPrevents failed startup condition
Contactor Delay ControlControls engagement timing
Reverse Torque LimitTypically reduced vs forward torque
Reverse Speed ClampLimits reverse speed
Direction Change Lockout TimerPrevents immediate reversal
Direction Change Delay TimerAdds delay before torque reapply
Torque Command FilterSmooths throttle-to-torque response
Current Slew Rate LimitLimits current rise/fall speed
Current Loop Saturation LimitCaps internal current demand
Iq/Id Decoupling GainImproves FOC control separation
Speed Loop Output ClampLimits speed loop authority
Speed Loop Integral LimitPrevents integral wind-up
Flux Observer GainRotor estimation responsiveness
Rotor Observer Filter ConstantSmooths rotor position estimation
Deadtime CompensationCorrects switching delay losses
PWM DeadtimePrevents transistor shoot-through
MOSFET Thermal ModelInternal temperature estimation (typically enabled in firmware)
Stall Detection ThresholdDetects non-rotating motor under load
Stall Current LimitLimits current during stall
Anti-Stall Recovery TimerDelay before retry
Slip Detection ThresholdDetects mismatch in expected speed
Slip Compensation GainAdjusts torque during slip
Overvoltage Regen SuppressionTypically enabled to protect battery from overvoltage
Regen Disable on Fault FlagCommonly enabled to disable regen during fault conditions
Fault Latch BehaviorLatchedRequires reset after fault
Fault Auto-Recovery EnableAllows automatic recovery
Watchdog TimerFirmware safety reset timer
Startup Torque Boost (Internal)Improves launch from stop
Startup Alignment CurrentHolds rotor before movement
Startup Alignment TimeDuration of alignment phase
Zero Speed Lock DetectionTypically enabled to detect stopped motor state
Neutral State Current ClampPrevents unintended movement
Hall Signal Debounce TimeFilters noisy hall signals
Hall Error TimeoutDetects signal loss
Encoder Signal Loss TimeoutDetects encoder failure
Resolver Signal Quality ThresholdMinimum valid signal level
Sensorless Transition ThresholdRPM where fallback may occur
Sensorless Fallback EnableAllows operation without sensors (firmware-dependent)
Throttle Plausibility CheckTypically enabled to prevent invalid throttle input
Brake-Throttle Override LogicCommonly enabled so brake input overrides throttle
CAN Timeout ThresholdDetects communication loss
Communication Loss Fallback ModeDefines behavior when communication is lost (disable / limp / coast)
ID ErrDiagnostic flag for identification failure

Additional Parameters (Firmware Dependent)

This section lists firmware-dependent parameters that may exist on other Kelly variants but are not visible in this dataset.

The Kelly KLS7230S controller may expose additional parameters depending on firmware version, controller revision, and configuration software. These are not present in this dataset but may appear in other controller variants.

Their absence in the table does not indicate missing functionality.

These parameters are often controlled internally by firmware, may not be visible or adjustable through standard Kelly configuration tools, and follow the same system relationships defined above. They may also override or interact with user-visible settings in the main configuration table.

Field Weakening

ParameterExample Value / RangeWhat It Does
Min Excitation5-15%Sets the lower excitation floor used when weakening begins
Max Excitation80-100%Sets the upper excitation limit available before weakening behavior changes
Field Weakening EnableOn / OffEnables or disables field weakening behavior
Flux Weakening %5-20% mild, 20-40% aggressiveControls how strongly the controller reduces effective field strength at high RPM

These parameters control high-speed operation beyond the motor’s normal voltage-limited speed range.

  • field weakening allows the motor to spin faster than its normal base speed at a given battery voltage
  • it works by reducing effective magnetic field strength at higher RPM
  • this increases top-end speed, but it does not create additional power

Behavior characteristics:

  • low values produce a mild top-speed increase with less heat
  • higher values can extend speed further, but current draw rises quickly
  • torque drops off more noticeably as speed increases
  • motor and controller temperature climb faster during sustained high-speed riding

Important:

  • field weakening does not increase total power, only extends usable RPM range
  • aggressive values can overheat the motor quickly
  • excessive weakening can make the bike feel faster at the top end but weaker and less efficient under load
  • real results depend heavily on battery voltage, gearing, motor characteristics, and load

Regenerative Braking Control

ParameterExample Value / RangeWhat It Does
Max Regen Current10-30A mild, 30-60A strongSets the upper limit for how much regen current the controller can send back into the battery
Regen Current Limit10-50ACaps regen output regardless of brake percentage settings
EBS Level1-3 light, 4-6 medium, 7-10 aggressiveSets the overall strength of electronic braking behavior, depending on firmware scale

These fields determine how much regenerative current the controller is actually allowed to apply.

  • these fields control how much braking force the controller can produce electrically
  • unlike brake percentage settings, they act as current-based limits on how much regen can actually happen
  • this is a primary factor in whether regen feels light, moderate, or very strong when the brake is applied

Behavior characteristics:

  • lower values produce gentler deceleration and less battery charging current
  • higher values increase braking force and make regen more noticeable
  • aggressive settings can make the bike feel abrupt when braking begins
  • regen is strongest at higher speed and naturally gets weaker as RPM drops

Important:

  • these limits may override or reshape BRK_SW / BRK_AD percentage settings
  • actual regen feel is usually a combination of brake percentage, regen current limits, and motor speed
  • excessive values can increase battery stress, BMS intervention, and motor heat during repeated braking
  • strong regen settings may feel good at speed but still taper off near low RPM because back EMF falls with speed

Torque and Speed Limits

ParameterExample Value / RangeWhat It Does
Torque LimitExample range: 60-100% typical, 100%+ less restrictedCaps maximum motor torque output
Max Torque CommandExample range: 50-100%Limits how much torque the controller will request internally
Absolute Speed LimitExample range: 12000-18000 RPMSets a hard ceiling on motor speed regardless of throttle input

These fields act as hard limits on what the controller is allowed to output.

  • these parameters act as upper limits on what the controller is allowed to do
  • they apply regardless of throttle position or rider input
  • they sit above other settings like throttle mapping and current limits

Behavior characteristics:

  • lower torque limits reduce acceleration and overall power feel
  • increasing torque limits improves launch and responsiveness
  • speed limits cap top speed even if the system has power to go faster
  • aggressive limits can make the bike feel unrestricted but increase system stress

Important:

  • these limits may override phase current and throttle mapping behavior
  • setting torque too low can make the bike feel flat or unresponsive
  • setting speed limits too low can prevent reaching expected top speed even with correct gearing and power
  • these are often used for safety, battery protection, or drivetrain longevity

Voltage Compensation

ParameterExample Value / RangeWhat It Does
Bus Voltage Compensation0-10% mild, 10-25% aggressiveAdjusts output to compensate for voltage sag under load
Power Limit vs VoltageLinear or stepped curveReduces available power as battery voltage drops

These parameters control how the controller responds to battery voltage sag during load.

  • these parameters adjust how aggressively the controller tries to maintain performance as voltage drops
  • instead of letting power fall naturally with voltage, compensation increases current draw to hold output

Behavior characteristics:

  • low compensation results in noticeable power drop as battery voltage sags
  • higher compensation keeps acceleration and power more consistent under load
  • aggressive settings increase current draw to maintain output
  • system may feel strong even at lower battery voltage, but at the cost of efficiency

Important:

  • higher compensation increases battery stress and heat
  • interacts directly with Bat Current Limit and overall system power draw
  • aggressive settings can increase voltage sag rather than reduce it under heavy load
  • behavior depends heavily on battery condition, internal resistance, and discharge capability

Control Mode and Behavior Flags

ParameterExample Value / RangeWhat It Does
Torque Mode / Speed ModeTorque (default), Speed (less common)Determines whether throttle controls torque output or targets a speed
Regen Enable ModesOff / Throttle Release / Brake Only / CombinedDefines when regenerative braking is allowed to engage
Direction Change ProtectionEnabled / DisabledPrevents unsafe direction changes while the motor is still rotating

These fields control the controller’s internal operating modes and logic behavior.

  • these parameters control how the controller interprets inputs and applies output
  • they change the overall behavior of throttle, braking, and direction handling
  • unlike tuning values, these act more like system-level switches

Behavior characteristics:

  • torque mode provides direct and predictable throttle response based on rider input
  • speed mode attempts to maintain a target speed, which can feel less natural on a bike
  • regen modes determine whether braking occurs on throttle release, brake input, or both
  • direction protection prevents immediate reversal, reducing drivetrain shock

Important:

  • typically firmware-controlled and not always exposed in user tools
  • incorrect mode selection can make throttle response feel unnatural or unstable
  • regen mode configuration can significantly change how the bike behaves when coasting or braking
  • direction protection is critical for safety and preventing mechanical damage

Additional Parameters (Extended Firmware Variants)

This section covers parameter families that may be user-visible in some Kelly firmware branches, engineering tools, or controller revisions, but are not present in this dataset.

The Kelly KLS7230S controller may expose additional parameters in other firmware branches, engineering tools, or controller revisions. These are not present in this dataset but are consistent with behavior seen across Kelly KLS variants.

Their absence in the table does not indicate lack of functionality.

These fields may be user-visible in some firmware, hidden in others, or partially controlled through internal logic that sits on top of the exposed parameter set.

Regenerative Behavior (Extended)

ParameterExample Value / RangeWhat It Does
Brk_Speed Limit100 RPMMinimum motor speed at which regenerative braking becomes active
Low Speed Regen CutoffExample range: 0-100 RPM below active regen regionFurther tapers or disables regen as speed approaches zero
Regen Ramp RateSlow / Medium / FastControls how quickly regen torque is applied
Regen Voltage ClampNear pack overvoltage thresholdLimits regen current as battery voltage approaches protection limit
Regen Current Slew LimitLow / Medium / High or firmware-dependent ramp rateLimits how quickly regen current can rise or fall

These parameters extend regenerative braking behavior beyond the standard exposed brake percentage and timing fields.

  • Brk_Speed Limit defines the minimum motor speed (RPM) at which regenerative braking becomes active
  • below this RPM, regen is reduced or effectively disabled because back EMF is too low to push current into the battery
  • this is the point where regen begins to engage and become usable
  • Low Speed Regen Cutoff defines an additional region where regen may be further limited or tapered as speed approaches zero
  • Regen Ramp Rate and Regen Current Slew Limit shape how quickly braking torque is applied and removed
  • Regen Voltage Clamp limits regenerative current as battery voltage approaches overvoltage protection

Behavior characteristics:

  • regen strength drops as speed approaches the Brk_Speed Limit threshold
  • below ~100 RPM, braking typically transitions from electrical regen to primarily mechanical braking
  • prevents unstable or jerky braking at very low speed
  • smooths braking engagement and release
  • prevents abrupt negative torque spikes
  • reduces the chance of overvoltage faulting during high-speed deceleration

Important:

  • may not appear in standard Kelly tools
  • may override or reshape BRK_SW / BRK_AD behavior
  • real regen feel is determined by both exposed settings and internal limits like Brk_Speed Limit

Thermal Management (Extended)

ParameterExample Value / RangeWhat It Does
High Temp Str CTypical example range: 120-150°CTemperature where the controller starts reducing output
High Temp Weak %Low / Medium / High or firmware-dependent scalingControls how aggressively power is reduced once thermal limiting starts
Thermal Derating SlopeShallow / Medium / SteepControls how quickly output falls as temperature rises
Thermal Foldback GainLow / Medium / HighShapes how strongly the controller folds power back under heat
Thermal Recovery RateSlow / Medium / FastControls how smoothly power returns after cooling

These parameters control how the controller reduces power as temperatures rise, before reaching full shutdown.

  • High Temp Str C defines the temperature where the controller starts reducing output
  • this is the point where power begins to get pulled back to prevent overheating
  • on most systems, this occurs noticeably before the hard cutoff (High Temp Cut C = 170°C in this case)
  • High Temp Weak % defines how aggressively power is reduced once thermal limiting starts
  • lower values result in gradual power reduction, higher values cause faster and stronger derating
  • Thermal Derating Slope, Thermal Foldback Gain, and Thermal Recovery Rate control how quickly power is reduced and how smoothly it returns after cooling

Behavior characteristics:

  • power is reduced gradually before reaching the shutdown temperature
  • under sustained load, output will continue to drop as temperature increases
  • repeated hard acceleration or high-speed riding will trigger earlier and stronger derating
  • power does not immediately return once temperatures drop; recovery is controlled and delayed
  • depending on settings, the system may feel strong initially but fade quickly under continuous load

Important:

  • not exposed in this dataset
  • works together with High Temp Cut C (170°C) and High Temp Resume (150°C)
  • High Temp Str C typically sits well below the cutoff to allow controlled derating instead of abrupt shutdown
  • has a major impact on how much power the system can sustain over time
  • this is one of the main reasons short bursts feel strong, but continuous riding feels weaker as heat builds

Torque and Speed Constraints (Extended)

ParameterExample Value / RangeWhat It Does
Max Torque ClampExample range: 80-120%Sets an internal hard ceiling on torque output regardless of other limits
Torque Limit vs Speed CurveLinear / stepped reductionReduces available torque as speed increases
Torque Derate vs RPMStarts ~60-80% of max RPMGradually lowers torque at higher motor speeds
Electrical Frequency ClampExample range: 800-1200 Hz, firmware-dependentCaps maximum electrical output frequency
Back EMF Compensation0-20%Adjusts output to account for increasing back EMF at high speed
Field Weakening Ramp RateSlow / Medium / FastControls how quickly field weakening is applied as speed increases

These fields shape deeper torque and speed limits that are not always visible in the standard UI.

  • these parameters shape how torque is delivered across the full speed range
  • they control the transition from strong low-speed acceleration to limited high-speed output
  • they operate on top of visible limits like Max Speed and Phase Current

Behavior characteristics:

  • strong torque at low speed gradually fades as RPM increases
  • prevents excessive current draw at high speed where efficiency drops
  • smooths the transition into top-speed operation
  • limits abrupt or unstable behavior near maximum speed
  • affects how aggressively field weakening engages at higher RPM

Important:

  • may appear only in certain firmware or controller variants
  • may override visible speed or current settings even when those values appear unchanged
  • top-speed behavior is often governed more by these parameters than by Max Speed alone
  • overly aggressive limits can make the bike feel strong off the line but weak at speed
  • overly loose limits can increase heat, instability, and system stress at high RPM

Sensor and Identification Extensions

ParameterExample Value / RangeWhat It Does
Hall Sequence ValidationEnabled / DisabledVerifies correct hall sensor transition order
Phase Alignment Offset±0-10° electricalApplies correction to align controller output with motor position
Auto-Identification State MachineRun on startup / manual triggerHandles automated motor identification and calibration
Phase Advance Angle (Dynamic)0-20° increasing with RPMAdvances timing as speed increases for efficiency
Commutation Advance MapSpeed-based curveDefines how phase advance changes across RPM range

These parameters control additional motor identification and commutation behavior beyond the visible sensor setup fields.

  • these parameters control how the controller understands rotor position and aligns electrical output with the motor
  • they refine timing, improve efficiency, and ensure correct commutation across all speeds
  • they operate continuously in the background once the system is running

Behavior characteristics:

  • correct values result in smooth operation and consistent torque delivery
  • phase advance improves efficiency and reduces heating at higher speeds
  • improper alignment can cause rough operation, noise, or reduced performance
  • identification routines ensure the controller matches the specific motor characteristics

Important:

  • may be partially exposed only through engineering or OEM tools
  • directly tied to motor identification success and sensor configuration
  • incorrect hall sequence or phase alignment can prevent operation or trigger faults
  • errors in this layer often appear as hard faults or startup failure rather than simple tuning issues

Voltage and Startup Management (Extended)

ParameterExample Value / RangeWhat It Does
Dynamic Current Limiting vs Voltage0-30% scalingReduces output as battery voltage drops under load
Power Limiting CurveLinear / stepped curveDefines how available power changes across voltage range
DC Bus Ripple FilterLow / Medium / High filteringSmooths rapid voltage fluctuations from the battery
DC Bus Voltage Averaging Window10-100 msDetermines how quickly voltage changes affect control decisions
Precharge Detection Threshold~60-90% of pack voltageDetects when safe precharge voltage is reached before enabling full power
Precharge Timeout100-1000 msSets how long the controller waits for precharge before faulting
Contactor Delay Control50-500 msDelays full engagement to protect components during startup

These parameters control higher-level power and startup management behavior.

  • these parameters control how the controller reacts to unstable or changing battery voltage
  • they also manage how the controller safely powers on and connects to the battery
  • they operate continuously during both startup and riding conditions

Behavior characteristics:

  • smooths power delivery during voltage sag or heavy load
  • reduces sudden drops or spikes in output caused by battery instability
  • prevents damaging current spikes during controller startup
  • affects how quickly the controller responds to voltage changes under load

Important:

  • may be hidden in standard user tools
  • directly interacts with Low Volt, Over Volt, and Bat Current Limit
  • aggressive current limiting can make the bike feel weak under load
  • insufficient filtering or delay can cause harsh startup behavior or fault conditions
  • startup reliability and consistency are heavily influenced by these parameters

Reverse and Direction Control (Extended)

ParameterExample Value / RangeWhat It Does
Reverse Torque Limit20-50% typicalLimits available torque when operating in reverse
Reverse Speed Clamp20-50% of forward speedCaps maximum reverse speed
Direction Change Lockout Timer200-1000 msPrevents immediate direction changes while motor is still spinning
Direction Change Delay Timer100-500 msAdds a delay before applying torque after a direction change

These parameters control additional reverse and direction change behavior.

  • these parameters control how the system behaves when switching between forward and reverse
  • they are primarily designed to protect the drivetrain and improve rideability
  • they operate automatically whenever a direction change is requested

Behavior characteristics:

  • reverse power is usually reduced to prevent abrupt or unsafe movement
  • reverse speed is limited compared to forward operation
  • direction changes are delayed to allow the motor to slow down before reversing
  • prevents sudden torque reversal that can stress mechanical components

Important:

  • may be hidden even when Change Dir is exposed in the main settings
  • intended primarily for safety and hardware protection
  • aggressive or disabled limits can cause harsh or damaging direction changes
  • overly restrictive values can make reverse feel weak or unresponsive
  • timing behavior can make direction changes feel delayed if not understood

Internal / Non-Exposed Control Parameters

See Kelly: Internal Control Behavior for this reference.

Related Articles