ONYX 41AH BMS Settings

Navigate these settings for both ONYX 41Ah battery stock settings and tuned settings configuration for optimal performance, range, and power.

  • Note that all temperature settings are in Celsius, not Fahrenheit.

Battery BMS App

Use the Overkill Solar BMS app or the Xiaoxiang BMS app to configure the ONYX 41Ah battery. Download links and instructions for the ONYX 41Ah battery BMS apps can be found below.


Battery and Cycle Capacity

  • Total Battery Capacity: Set this field to the full capacity of the battery in milliamp-hours (mAh). For a 41Ah battery, this value would be 41000.

  • Total Cycle Capacity: Set this field to 80% of the total capacity. For a 41Ah battery, this value would be 32800.


BMS Stock Configuration

Capacity Configuration

Field Value
Number of Cell 20
Total Battery Capacity 41000
Total Cycle Capacity 32800
Cell Full Voltage 4150
Cell Minimum Voltage 3000
Cell Self Discharge 0.2
Cell 100% Cap. Voltage 4150
Cell 90% Cap. Voltage 4075
Cell 80% Cap. Voltage 4000
Cell 70% Cap. Voltage 3900
Cell 60% Cap. Voltage 3800
Cell 50% Cap. Voltage 3700
Cell 40% Cap. Voltage 3600
Cell 30% Cap. Voltage 3450
Cell 20% Cap. Voltage 3300
Cell 10% Cap. Voltage 3150

Balancer Configuration

Field Value
Start Voltage 4000
Delta to Balance 15
Balancer Enabled (On) Green
Bal. Only When Charging (On) Green

Function Configuration

The field switch “Display Celsius” can be changed according to you preference.

Field Value
SW Switch Circuit Enabled (Off) Gray
Display Celsius (Off) Gray

Protections

Field Trigger Release Delay
Cell Over Voltage 4250 4150
Cell Under Voltage 2700 3000
Batt Over Volt. 85000 83000
Batt Under Volt. 54000 60000
Charge Over Curr. 70000 32
Discharge Over Curr. (80 Amp BMS) 90000 32
Discharge Over Curr. (100 Amp BMS) 110000 32
Charge Over Temp 65 55 2
Charge Under Temp -5 0 2
Discharge Over Temp 70 60 2
Discharge Under Temp -10 0 2

NTC Enable

NTC refers to the temperature sensors located on the BMS board and around the battery. Some batteries only utilize NTC1, NTC2, and NTC4 sensors.

Field Box
NTC1 Checked
NTC2 Checked
NTC3 Checked
NTC4 Checked
NTC5 Not Checked
NTC6 Not Checked
NTC7 Not Checked
NTC8 Not Checked

Level 2 Protections

Field Trigger Delay
Level 2 Overcurrent 720 320
Level 2 Overvoltage 4400 8
Level 2 Undervoltage 2500 8

Level 3 Protections

Field Trigger Delay Reset
Level 3 Overcurrent (Short Circuit) 2000 400 5